█ Features:
- Dalistandardinterface and standard dT6 protocol comply with Dali 144 standards
- 2.Dali2 certification, Dali member
- Digital control output is adopted, and there is flicker free
- AC input 100-250V range
- Aluminumshellnatural air cooling, moisture-proof, heat conduction, silica gel heat dissipation process
- 6.Deep dimming design
- 7.Multiple protection functions
- IP67 waterproof design
█ Application:
- 1. Led monochrome light source
- Villa intelligent lighting
- Wirelessintelligentlighting system can be accessed
- Subway lighting
- Highend commercial lighting
█Specification:
Model | QXP-P30DA42 | QXP-P45DA42 | |
OUTPUT | Output Voltage | 9-42Vdc | 9-42Vdc |
Max Output Voltage | 42Vdc | 42Vdc | |
Non-load Output Voltage | 51Vdc | 51Vdc | |
Output Current | 500-700mA | 700-1050mA | |
Output Power | 4.5W~29.4W | 6.3W~44.1W | |
Strobe Level | No Flicker | ||
Dimming Range | 0~100%, LEDstart at 0.003%possible. | ||
PWM Dimming Frequency | >3600Hz | ||
Current Accuracy | ±5% | ||
Power down mode | memory function when power down | ||
INPUT | Dimming Interface | DALI (IEC62386)Signal control current < 2mA | |
Input Voltage Range | 100-250Vac | ||
Frequency | 50/60Hz | ||
Input Current | <0.32A ac110v | <0.48A ac110v | |
Power Factor | PF>0.99/230V ac(at full load) | ||
THD | 230Vac@THD <8% (at full load) | ||
Efficiency(typ.) | 85.5% | 87% | |
Inrush Current(typ.) | cold start20A@230Vac | cold start20A@230Vac | |
Anti Surge | L-N: 2kV | ||
Leakage Current | <0.25mA/230Vac | ||
ENVIRONMENT | Working Temperature | ta: 45°C tc: 80 °C | |
Working Humidity | 20 ~ 95%RH, non-condensing | ||
Storage Temp., Humidity | -40 ~ 80°C, 10~95%RH | ||
Temp.Coefficient | ±0.03%/°C(0-50)°C | ||
Vibration | 10~500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes. | ||
PROTECTION | Over-heat Protection | Intelligently adjusting or turning off the output current if the PCB temperature ≥110°C, , auto recovers. | |
Over Load Protection | Shut down the output when rated power≥102%, auto recovers. | ||
Short Circuit Protection | Shut down automatically if short circuit occurs, auto recovers. | ||
Non-load Protection | output Constant Voltage. | ||
SAFETY & EMC | Withstand Voltage | I/P-O/P: 3750Vac | |
Isolation Resistance | I/P-O/P: 100MΩ/500VDC/25°C/70%RH | ||
Safety Standards | IEC/EN61347-1, IEC/EN61347-2-13 | ||
EMC Emission | EN55015, EN61000-3-2 Class C, IEC61000-3-3 | ||
EMC Immunity | EN61000-4-2,3,4,5,6,8,11, EN61547 | ||
Strobe Test Standard | IEEE 1789 | ||
Waterproof grade | IP67 | ||
OTHERS | Dimension | 142×47.5×32.2mm(L×W×H) | |
Packing | PE bag | ||
Weight(G.W.) | 330g±10g | ||
Note: the current value of the product shall be determined when placing an order, and the current of the finished product cannot be changed |
█Relationship Diagrams:
█Dimensions :
█ Product Label:
█Wiring:
Input terminal wiring: 35cm wire gauge 0.75×3, brown for L, blue for N, green for ground wire, stripping
head 7-10mm (TIN)
Output terminal wiring: 35cm wire gauge 0.75×2, red is positive, black is negative, stripping head
7-10mm (TIN)
Signal terminal wiring: 30cm wire gauge 0.5×2, stripping head 7-10mm (TIN)
█The use of guidance:
Unless otherwise specified, all specifications and parameters shall be measured under the input of 230VAC, rated load and 25 ℃ ambient
temperature.
matters needing attention:
Note 1: when using this power supply, please pay attention to distinguish the input end and output end. Please connect the wire correctly and
power on only after checking it;
Note 2: please connect the load at the DC output first, confirm it is correct, and then turn on the power supply; In the constant current mode, if
the open circuit is powered on, please turn off the power and wait for the data stored at the output terminal
After the electric energy is released, connect the LED, otherwise the LED may be burned out;
Note 3: this power driver is only used for LED lamps. The input voltage range of the product is AC 100-250V, which is used within the specified
output voltage and current range,
The ambient temperature is – 20 to + 45 ℃, and the surface cannot be covered with heat insulation cotton and other items that block the heat
dissipation of the product, which meets the service conditions of the product, this product enjoys a five-year free warranty.
█The abnormal conditions and the corresponding treatment methods:
1, the LED lamp doesn’t bright after the dimming driver is connected at the first time ,please turn off the AC input and check as follow:
- a) Whether or not DC output bad contact;
b)Whether DC output polarity is reversed, or the LED board is welded anti;
c)Whether AC input is bad contact; test after eliminating these failures.
2, the device has good connection, LED lights, but the LED flicker, please turn off the AC input, then check the DC output:
- a) overload, under load.
- b) Whether or not the parameters and actual parameters match.
3, please timely communicate with us if you any questions in the using, we will try our best to solve the problems with you.
█Statement:
The pictures and specifications is for reference only, in kind prevail, specifications are subject to change with further notice.
█Statement:
Digital Addressable lighting Interface (DALI)
DALI slave unit will send data only master unit requests, that is, adopt command answering mode
There are 64 slave units at most in the same DALI network, each unit has a separate address(short address), A salve unit can also
be assigned to a certain group, and a slave unit can belong to different group, salve unit can exist up to 16 groups at the same
time, each unit can set 16 scenarios.
The main features of the DALI protocol
1)Asynchronous serial communication.
2)1200 baud rate, using the Manchester encoding format.
3)Two lies differential signal.
4)The high level when differential voltage is larger than 9.5V.
5)The low level when differential voltage is less than 6.5V.
6)The master unit controls communication process.
7)One DALI bus can connect with 64 slave units.
8)Each slave unit can be individually addressed.
DALI Electrical Specification
Under the idle state, from machine unit method to control the bus:
1)High Output power at ordinary time, not to interference in the hold signal.
2)Output low electricity at ordinary time, directly to the DALI bus short circuit to each other.
3)DALI bus maximum current of 250mA
4)Not a two-way communication at the same time.
5)Transmission cable up to 300 meters, or pressure drop is no more than 2v